TM 9-1240-216-34
4-21. HIGH VOLTAGE CABLE ASSEMBLY INSTALLATION (CONT)
FRAME 2
Procedure
Step
Put a thin coat of electrical insulating compound on center leg (1) of cable assembly (2)
1.
(JPG).
Put center leg (1) of cable assembly (2) into receptacle (3) until shoulder on center leg
2.
touches receptacle.
Make sure that terminal of white wire (4) from electron tube (5) is also connected to
3.
terminal (6) of board assembly (7).
4.
Using screwdriver, attach terminal A of cable assembly (2) to terminal (6) of board
assembly (7) with lockwasher (8) and screw (9).
5.
Do steps 3 and 4 again to connect terminal B of cable assembly (2) to terminal of
board assembly inside terminal housing (10).
Screw receptacle cap (11) onto receptacle (3).
6.
NOTE
FOLLOW-ON MAINTENANCE
END OF TASK
Para 4-21 Cont
4-40