TM 9-1240-216-34
Section 7. RECEPTACLE
4-22.
RECEPTACLE MAINTENANCE PROCEDURES INDEX
Reference (para)
Task
Removal
Installation
4-23.
RECEPTACLE REMOVAL
TOOLS: 3/16" flat tip screwdriver
PERSONNEL: One
EQUIPMENT CONDITION: Body assembly on work bench; power disconnected
PRELIMINARY PROCEDURES: Remove cover assembly (para 4-14 )
FRAME 1
Procedure
Step
1.
Using screwdriver, remove four screws (1), four lockwashers (2), and three chains (3)
from receptacle (4) and body assembly (5).
Unscrew and remove receptacle cap (6).
2.
3.
Using your hand, turn receptacle (4) slightly from side to side and pull until receptacle
(4) is out of body assembly (5).
4.
Remove preformed packing (O-ring) (7) from groove in hole in body assembly (5)
where receptacle (4) was removed.
Using your fingers, from inside of body assembly (5) pull high voltage cable (8) in
5.
through hole (9).
END OF TASK
Para 4-22
4-42
Vol II