FRAME 1
Procedure
Step
WARNING
Dry cleaning solvent can catch on fire. Keep it and all
material that can catch on fire away from flames. Use
only in a room with a lot of fresh air.
Using cloth dampened with dry cleaning solvent, remove all old sealing compound from
1.
receptacle (1) and receptacle hole in body assembly (2).
Install preformed packing (O-ring) (3) in groove in receptacle hole of body assembly (2),
2.
Install and position receptacle (1) into body assembly (2).
3.
Install receptacle cap (4) on receptacle (1).
4.
NOTE
In step 5, three of the four lockwashers and screws hold
cap chains (5).
5.
Using screwdriver, install three chains (5), four lockwashers (6), and four screws (7).
6.
Using sealing gun with adapter, force sealing compound in receptacle sealing hole (8) in
body assembly (2) until receptacle (1) is completely sealed (JPG).