TM 9-1240-216-34
HIGH VOLTAGE CABLE ASSEMBLY INSTALLATION
4-21.
TOOLS: 3/16" flat tip screwdriver
Electrical insulating compound (item 2, App A )
SUPPLIES:
PERSONNEL: One
REFERENCES: JPG 4lC for application of eletrical insulating compound
EQUIPMENT CONDITION: Body assembly on work bench; power disconneted
NOTE
Frame 1 is for M19 and M24 new configurations. Frame 2
is for M19 and M24 old configurations.
FRAME 1
Procedure
Step
Put a thin coat of electrical insulating compound on center leg (1) of cable assembly (2)
1.
(JPG).
Put center leg (1) of cable assembly (2) in receptacle (3) until shoulder on center leg
2.
touches receptacle (3).
NOTE
FOLLOW-ON MAINTENANCE
Install both terminal board assemblies (para 4-18, frame
1 only).
END OF TASK
Para 4-21
4-38
Vol II