TM 9-1240-380-34
6-20.
PROTECTIVE PLUG, CLAMP, WIRE, SLEEVE ASSEMBLY, CONTACT
(ELECTRICAL), AND CONNECTOR INSTALLATION (CONT)
FRAME 2
Procedure
Step
1.
Check that packing (1) is seated in groove. Check packing (1) for wear or cracks.
Replace if damaged.
2.
Put a thin film of grease on surface of packing (1) (JPG).
While holding housing assembly (2) in place, use 5/16" flat tip screwdriver and 5/16"
3.
offset screwdriver to install four washers (3) and four screws (4).
4.
Put a thin film of grease on surface of packing (5) (JPG).
5.
Place packing (5) on cell assembly (6).
While holding cell assembly (6) in place, use 3/16" Allen wrench to install four washers
6.
(7) and four screws (8) in elbow assembly (9).
7.
Put a thin film of sealing compound on threads of setscrew (10) (JPG).
8.
Using 5/64" Allen wrench, install setscrew (10).
9.
Using 1/8" Allen wrench, install setscrew (11) in elbow assembly (9).
NOTE
FOLLOW-ON MAINTENANCE:
Assemble cap assembly, converter, and power supply
Install cap assembly, electron tube and collar (para
END OF TASK
Vol II
6-36