TM 9-1240-401-34&P
2-15. M146 TELESCOPE MOUNT FINAL INSPECTION AND ADJUSTMENT-continued
e. CHECKING DEFLECTION KNOB MECHANISM RUNNING TORQUE
1 With torque wrench and adapter (8599922), rotate
deflection knob (1) clockwise and counterclock-
wise.
NOTE
Torque wrench should indicate running torque
of 56 to 72 ounce-inches (0.395 to 0.508
N-m). If running torque is not within specified
limits, adjust as directed in steps 2 thru 6.
2 Loosen self-locking nut (2).
3 Loosen setscrew (3).
4 Using fabricated spanner wrench, adjust threaded
ring (4) until required running torque is obtained.
5 Tighten setscrew (3).
6 Tighten self-locking nut (2).