TM 9-1240-400-34&P
5-17. MAINTENANCE OF TELESCOPE MOUNT SUBASSEMBLY AND BASE ASSEMBLY (CONT).
DISASSEMBLY (CONT)
17 Remove pivot (32) and components as a unit from
base (18).
18 Remove 16 rings (36), tapered pin (37), and dial stop
(38) from pivot (32).
19 Remove bevel gear (39), spring (40), screw (41), key
(42), two pins (43), and cluster gear (44) from pivot
(32).
20 Remove pin (45) from pivot (32).
21 Remove three screws (46), bevel gear (47), and
preformed packing (48) from base (18). Discard
preformed packing.
22 Remove pin (49) only if damaged.
23 Remove pin (50) and pin (51) only if damaged.
CLEANING
Clean all parts per TM 9-254.
REPAIR
1
If adapter is broken or damaged, repair is by replacement of next higher assembly.
2
If base is broken or damaged, repair is by replacement of next higher assembly.
3
Repair is by replacement of authorized parts as required. Refer to appendix B.
548