TM 9-1240-400-34&P
2-10.
MAINTENANCE OF M115 PANORAMIC TE
DISASSEMBLY
1
Remove three setscrews (1) and head assembly (2)
from body assembly (3).
2
Remove two screws (4) and identification plate (5).
3
Remove and discard preformed packing (6).
4
Remove three setscrews (7) and setscrew (8) from
body assembly (3).
5
Remove two screws (9) and stop (10).
6
Turn collar (11) counterclockwise to disengage body
(3) from elbow assembly (12).
7
Remove spring tension washer (13) and positive
clutch half (14) from body assembly (3).
8
Remove preformed packing (15) from groove in
elbow assembly (12). Discard preformed packing.
CLEANING
Clean all parts per TM 9-254.
REPAIR
1
Head assembly is a repairable assembly; refer to page 2-22.
2
Body assembly is a repairable assembly; refer to page 2-28.
3
Elbow assembly is a repairable assembly; refer to page 2-50.
Repair is by replacement of authorized parts as required. Refer to appendix B.
2-20