TM 9-1240-400-34&P 9
1
Apply sealant adhesive (item 5, appx C) to threads
8
Apply sealant adhesive (item 5, appx C) to threads
of mechanical post (1).
of externally threaded ring (11).
2
Install spring (2), detent plunger
(3),
and
9
Using tubular spanner wrench (7597638), install
mechanical post (1) to adapter (4).
externally threaded ring (11) on adapter (4).
10
Insert lamp base portion of overlay assembly (8)
3
Install cover (5), torsion spring (6), and rod (7).
into contact of adapter (4).
4
Pull wire with lamp base through to the front of
11
Position wire in recessed area to accommodate
overlay assembly (8).
cap assembly (12).
5
Install overlay assembly (8) onto adapter (4).
12
Install cap assembly (12) and two screws (13).
6
Apply sealant adhesive' (item 5, appx C) to tips of
13
Apply sealant adhesive (item 5, appx C) to outer
three screws (9).
edge of cap assembly (12).
7
14
Tighten three screws (9).
three screws (9).
Section V. GENERAL SUPPORT MAINTENANCE
2-10.
MAINTENANCE OF M115 PANORAMIC TELESCOPE.
This task covers:
a. Disassembly
c.
Repair
b. Cleaning
d.
Reassembly
INITIAL SETUP:
Equipment Conditions
Tools and Special Tools
M1 15 Panoramic telescope removed from
Shop equipment, electronic: system
M11 A2 howitzer (TM 9-2350-304-20-2)
maintenance, (SC 5180-95-CL-B29)
Torque adapter (figure 4, appx D)
General Safety Instructions
Materials/Parts
Preformed packing (8587449-2)
Use adhesives, cleaning solvents,
Preformed packing (8587449-5)
and sealing compounds in well-
Sealing compound (item 10, appx C)
ventilated area away from open
Silicone compound (item 11, appx C)
flame. Adhesives, cleaning sol-
vents, and sealing compounds are
References
harmful to skin and clothing, can
TM 9-254
burn easily, and may give off harm-
ful vapor.
2-19