TM 9-1240-380-34
INFRARED BODY ASSEMBLY INSPECTION UPON RECEIPT (CONT)
3-5.
FRAME 5
Reference
Maintenance Action
Procedure
Step
Tighten. Replace if missing.
1.
Using .050" Allen wrench,
check that setscrew (1) is
tight.
...
If missing or damaged, tell
Check that plug (2) is not
2.
your supervisor.
missing.
If knob slips on clutch,
Without pulling out boresight
3.
replace knob assembly.
knobs (3), check that each
knob is firmly seated against
fixed clutch.
Replace knob assembly if
Pull out each boresight knob
4.
binding.
(3). Turn each knob (3) and
check for binding.
Clean. Replace knob assembly
Check that two scales (4) can
5.
if scales cannot be read.
be read.
...
Check that name plate (5)
If it cannot be read, tell your
6.
can be read.
supervisor.
...
Tighten. Replace if missing.
Using 1/ 8" screwdriver, check
7.
that four screws (6) are tight.
NOTE
FOLLOW-ON MAINTENANCE:
Correct faults listed on DA
Form 2404 that may affect
the checkout procedure.
Do checkout procedure
END OF TASK
Vol II