TM 9-1240-216-34
BODY COVER INSTALLATION
4-15.
TOOLS: Hydraulic sealing gun
1/4" flat tip screwdriver
Pocket knife
Sealing compound (item 8, App A)
SUPPLIES:
Dry cleaning solvent (item 9, App A)
PERSONNEL: One
REFERENCES: JPG 4lC for sealing procedures
EQUIPMENT CONDITION: Body assembly on work bench; power disconnected
FRAME 1
Procedure
Step
WARNING
Dry cleaning solvent can catch on fire. Keep it and all
material that can catch on fire away from flames. Use
only in room with a lot of fresh air.
1.
Using pocket knife, scrape off old sealing compound. Using dry cleaning solvent on cloth,
clean off any remaining old sealing compound from cover (1) and body assembly (2).
Place cover (1) on body assembly (2).
2.
3.
Using screwdriver, put in and tighten 15 lockwashers (3) and 15 screws (4).
4.
Using sealing gun, force sealing compound in 8 sealing holes (5) of cover (1) until
completely sealed (JPG).
NOTE
FOLLOW-ON MAINTENANCE
END OF TASK
Para 4-15
4-22
Vol II