BODY ASSEMBLY INSPECTION UPON RECEIPT
3-4.
FRAME 2
Reference
Maintenance Action
Procedure
Step
Tighten. Replace if missing.
Using #0 Phillips screwdriver,
1.
check that two screws (1) are
tight.
Replace latch or cotter pin if
Check that latch (2) moves
2.
missing.
smoothly and that cotter pin
(3) is not missing.
Using 9/64" Allen wrench,
3.
Tighten. Replace if missing.
check that two screws (4) are
tight.
...
Tighten. Replace if missing.
Using #2 Phillips screwdriver,
4.
check that six screws (5) are
tight.
...
Tighten. Replace if missing.
Using #2 Phillips screwdriver,
5.
check that four screws (6) are
tight.
...
Tighten. Replace if missing.
Using jewelers screwdriver,
6.
check that two screws (7) are
tight.
...
If binding, tell your supervisor.
Check eyepiece (8) turns from
7.
stop to stop.
...
Tighten. Replace if missing.
Using jewelers screwdriver,
8.
check that three screws (9)
are tight.