C 2, TM 9-6650-221-35
Figure 6-9. Housing assembly 8589901 - exploded view.
b. Installation.
6-18. Replacement of Electrical Receptacle
Connector 5935-881-7775
carefully noting the polarity.
a. Removal.
(2) Unsolder the wires from the connector,
determining
the
correct
polarity
of
the
semiconductor device.
(3) Disassemble items 16 through 18 (fig. 6-
(2) Assemble in sequence, items 10 through 7
b. Inspection. Inspect the connector for bent or
broken pins, cracked insulation, and defective threads.
c. Installation.
6-14