ARMY TM 9-1240-379-34
MARINE CORPS TM 04332A-34
3-5. INFRARED BODY ASSEMBLY MAINTENANCE INSTRUCTIONS. (cont)
DISASSEMBLY (cont)
NOTE
NOTE
The solid power supply has
Parts in step 6 are to be
two bayonet-type slots which,
removed as an assembly.
when assembled with the
spring tension washer and
6 Remove pinned sleeve (5), spring tension
pinned sleeve, are interlocked
washer (7), and solid power supply (6)
and will be removed as an
assembly.
7 Remove solid power supply (6) from
5 Rotate pinned sleeve (5) counterclock-
pinned sleeve (5). Remove spring tension
wise as far as possible, disengaging out-
washer (7) and discard.
put end of solid power supply (6) from
interlocking pins of connector.
3-10