ARMY TM 9-1240-379-34
MARINE CORPS TM 04332A-34
2-5. INFRARED BODY ASSEMBLYMAINTENANCE INSTRUCTIONS. (cont)
DISASSEMBLY
1 Loosen two setscrews (1) and turn
5 Remove gasket (8) and discard.
eyepiece assembly (2) counterclockwise
to remove.
6 Remove converter regulator (9) or
battery.
CAUTION
Damage may result if electron
NOTE
tube is exposed to bright
The solid power supply has
sunlight or high intensity ar-
two bayonet-type slots which,
tificial light.
when assembled with the
spring tension washer and
2 Remove eyepiece assembly (2), electron
pinned sleeve, are interlocked
and will be removed as an
body assembly (5).
assembly.
NOTE
7 Rotate pinned sleeve (10) counterclock-
The antipilferage seal will not
wise as far as possible, disengaging out-
be replaced.
put end of solid power supply (11) from
interlocking pins of connector.
3 Cut wire of antipilferage seal (6), if pres-
ent, and remove from cap assembly (7).
Discard antipilferage seal.
4 Remove cap assembly (7) with attached
gasket (8).
2-28