TM 9-1240-285-34&P
INSPECTION UPON RECEIPT (CONT)
3-2.
FRAME 3
Maintenance Action
Reference
Procedure
Step
...
Tighten. Replace if
1.
Using 3/ 8`' flat tip screwdriver,
missing.
check that plug (1) is tight.
...
2.
Tighten. Replace if
Using 3/32" Allen wrench, check
missing.
that four setscrews (2) are tight.
...
Tighten. Replace if
3.
Using 3/32" Allen wrench, check
missing.
that two setscrews (3) are tight.
...
Tighten. Replace if
4.
Using 3/ 16" flat tip screwdriver,
missing.
check that setscrew (4) is tight.
Replace dial scale.
5.
Check that dial scales (5) are not
and 4-13
dented, that they turn freely
without binding and that
graduations can be seen clearly.
Replace if missing.
6.
Check that plug (6) is not missing.
Tighten. Replace if
7.
Using 3/ 8`' flat tip screwdriver,
missing.
check that plug (7) is tight.
TM 43-0139
Paint chipped or
Check telescope mount for chipped
8.
scratched area.
or scratched paint.
NOTE
FOLLOW-ON MAINTENANCE
Correct faults listed on DA Form 2404
that may affect the checkout procedure.
END OF TASK
3-6
Vol II