TM 9-1240-401-34&P
8
Apply adhesive to lip of adapter assembly (10)
where lens (42) seats.
9
Install lens (42) and electrical lead (40) in adapter
assembly (10) with raised brass portion of contact
facing outward.
10
Apply adhesive to two machine screws (43).
11
Install azimuth rotating counter (45) on adapter
(44) and two machine screws (43).
12
Seal heads of two machine screws (43) with
adhesive.
13
Using solder and flux, solder electrical lead (40) to
headless shoulder pin (41).
14
Using 1/2 and 33/64 inch tubular spanner wrench,
install externally threaded ring (39) and stake in
place using adhesive.
15
Pull wire (37) with lamp base through to the front of
the overlay assembly (36) and position overlay
assembly (36) onto adapter assembly (10).
16
Using 11/16 and 45/64 inch tubular spanner wrench,
install retaining ring (38).
17
Insert lamp base portion of overlay assembly (36)
into electrical lead (40). Position wire in recessed
area to accommodate protective cap (35).
18
Apply adhesive to inside edge of protective cap (35).
19
Install protective cap (35) and secure with two
machine screws (34). Remove any excess adhesive
from outside edge of protective cap.
20
Apply sealing compound to post (29).
21
Install detent plunger (30) in adapter assembly (10).
22
Install post (29) in detent plunger (30) and secure
with setscrew (28).
23
Install spring (27) and plug (26).
24
Install access door (32), spring (33), and headless
straight pin (31).
Change 1