TM 9-1240-401-34&P
4-13. M145/M145A1 TELESCOPE MOUNT MAINTENANCE INSTRUCTIONS
a. Disassembly b. Repair
c. Assembly
This task covers:
Tools
Tool Kit, Electronic System, Repair, Field Mainte-
nance(SC5180-95-CL-B29)
Oil, lubricating (Item 9, appx B)
Sealing compound (Item 13, appx B)
Torque adapter (Item 6, appx F)
References
Torque wrench (Item 36, appx F)
TM 9-254
..
ment Condition
M145/M145A1 telescope mount installed on
Grease (Item 6, appx B)
howitzer.
t
1
a. Disassembly
I
1
Remove three machine screws (1), three lock-
washers (2), and plate insulator (3). Discard lock-
washers.
Remove three machine screws (4), three lock-
2
washers (5), and three wires (6) with three lug ter-
minals (7) and three sleeves (8) attached. Discard
Iockwashers.
Remove two machine screws (9), two Iockwashers
3
(10), two wires (11) with two lug terminals (12) and
two sleeves (13) attached, plate (14), and plate
insulator (15). Discard Iockwashers.
Remove machine screw (16), Iockwasher (17), and
4
retaining strap (18). Discard Iockwasher.
5
Remove two machine screws (19), disk insulator
(20), and disk insulator (21).
6
Remove machine screw (22) and nut (23) from two
lug terminals (24).
4-11