TM 9-1240-400-34&P
5-12.
MAINTENANCE OF TELESCOPE MOUNT SUBASSEMBLY LOWER ASSEMBLY.
This task covers:
a. Disassembly
c.
Repair
b. Cleaning
d.
Reassembly
INITIAL SETUP:
Equipment Conditions
5-13 M137 telescope mount use assembly
Tools and Special Tools
disassembled
Tool kit, electronic: system maintenance
(SC 5180-95-CL-B29)
General Safety Instructions
Adjustable spanner wrench (8284045)
Materials/Parts
Aircraft grease (item 8, appx C)
Sealing compound (item 10, appx C)
Use adhesives, cleaning solvents, and
Self-locking nut (8215831)
sealing compounds in well-ventilated
area away from open flame. Adhesives,
cleaning
solvents,
and
sealing
compounds are harmful to skin and
References
clothing, can bum easily, and may give
TM 9-254
off harmful vapor.
TM 9-2350-304-10
DISASSEMBLY
NOTE
M137 telescope mount upper assembly
housing shown removed for clarity.
1
Unsolder two electrical wires (1) and remove
from four electrical contacts (2).
2
Remove four electrical contacts (2) and four
5-28