TM 9-1240-400-34&P
4-11.
FINAL INSPECTION INSTRUCTIONS (CONT).
DEFLECTION LOCKING TORQUE
1
Use torque adapter (figure 2, appx D) and torque
wrench to apply a torque of 30.00 in.-lb (3.39 N-m),
clockwise, to capscrew (1).
2
Use torque adapter (figure 1, appx D) and torque
wrench to apply a torque of 4.00 in.-lb (0.45 N-m) to
eccentric plug (2). The line of sight of the collimator
telescope shall not change.
DEFLECTION ADJUSTING RANGE
1
Loosen screw (1).
2
Rotate eccentric plug (2) to move the collimator
telescope (3) through a range of 12 mils, either side
of center, as indicated by the reference markings at
each end, or the horizontal line of the test target.
4-26