ARMY TM 9-1240-379-34
MARINE CORPS TM 04332A-34
2-4. DAYLIGHT BODY ASSEMBLYMAINTENANCE INSTRUCTIONS. (cont)
DISASSEMBLY (cont)
WARNING
Detent plunger is under spring
tension. Be careful when
removing or injury may result.
10 Remove retaining ring (20) from detent
plunger (21).
11 Remove detent plunger (21) and helical
spring (22).
12 Remove two machine screws (23) and
(6).
NOTE
The electrical wire provides
the power source from the
contact to the reticle lamp ter-
minal. Replace only as
required.
13 Loosen and remove setscrew (25) and
lift out countact (26), together with con-
necting wire.
14 Unsolder wire from contact (26);
remove contact.
15 Loosen and remove lampholder (27),
gasket (28), and incandescent lamp
(29). Discard gasket (28) if
unserviceable.
16 Using tubular spanner wrench, remove
e x t e r n a l l y threaded ring (30).
2-18