TM 9-1240-380-34
CELL ASSEMBLY INSTALLATION
APPLICABLE CONFIGURATIONS: M36
TOOLS: 5/64", 3/ 16" socket head screw key (Allen wrench or equivalent )
8" adjustable wrench
SUPPLIES:
PERSONNEL: One
REFERENCES: JPG 4lC for Sealing
Lubricating
EQUIPMENT CONDITION: Infrared body assembly on work bench, power off
Procedure
Put a thin film of grease on surface of packing (1) (JPG).
Using adjustable wrench, install packing (1) and tube (2) in housing assembly (3).
Put a thin film of grease on surface of packing (4) (JPG),
Place packing (4) on cell assembly (5).
While holding cell assembly (5) in place, use 3/16" Allen wrench to install four washers
(6) and four screws (7),
Put a thin film of sealing compound on threads of setscrew (8) (JPG).
Using 5/64'" Allen wrench, install setscrew (8) in cell assembly (5).
NOTE
FOLLOW-ON MAINTENANCE:
END OF TASK
Vol II