TM 9-1240-401-34&P
c. Installation
1
Install wiring harness (8) on side of reticle cage
assembly (7) and secure with clamp (10) and
machine screw (9).
Install reticle cage assembly (7) in housing (5) be-
2
ing careful not to damage wiring harness (8).
Install threaded ring (6) in housing (5) using fabri-
3
cated spanner wrench.
4
Apply grease to two new preformed packings (4)
and install in grooves of two access covers (3).
Install two covers (3) on housing (5) and secure
5
with eight new Iockwashers (2) and eight cap
screws (1).
3-26. WIRING HARNESS MAINTENANCE INSTRUCTIONS
a. Removal b. Disassembly c. Repair d. Assembly e. Installation
This task covers:
Reticle cage assembly removed, M118A3
Tool Kit, Electronic System, Repair, Field Mainte-
Reticle cage assembly removed, M118A2
nance(SC5180-95-CL-B29)
Level assembly removed, M118A3
Level assembly removed, M118A32
Insulation sleeving (Item 16, appx B)
Tape (Item 20, appx B)
Cover assembly removed, M118A3
Cover assembly removed, M118A2
TM 9-254