FRAME 1
Procedure
Step
Clean lenses on both ends of image intensifier tube (1) (JPG) (TM 9-254).
1.
Screw extractor tool (2) on the tube (1).
2.
Line up the pins on the tube (1) with the connector (3), Push in on the tube (1) to
3.
plug in the connector (3) on the adapter assembly (4). Unscrew extractor tool.
4.
Clean lenses of eyepiece assembly (5) (JPG).
5.
Screw the eyepiece assembly (5) onto the adapter assembly (4).
6.
Using Allen wrench, tighten two setscrews (6).
NOTE
FOLLOW-ON MAINTENANCE:
END OF TASK