6-19.
PROTECTIVE PLUG, CLAMP, WIRE, SLEEVE ASSEMBLY, CONTACT
(ELECTRICAL), AND CONNECTOR REMOVAL (CONT)
FRAME 1
Procedure
Using 5/64" Allen wrench, remove setscrew (1).
Using 3/16" Allen wrench, remove four screws (2), four washers (3), cell assembly (4),
and packing (5) from elbow assembly (6).
Using 5/16" flat tip screwdriver and 5/ 16" offset screwdriver, remove four screws (7)
and four washers (8).
Be careful not to break wire connection to elbow
assembly.
Carefully pull housing assembly (9) away from elbow assembly (6).
Using 1/16" Allen wrench, remove two setscrews (10).
Using 1/8" Allen wrench, remove setscrew (11) from elbow assembly (6).
GO TO FRAME 2