C1, TM 9-1240-318-35
Section III. INSPECTION IN DIRECT SUPPORT, GENERAL SUPPORT,
AND DEPOT MAINTENANCE SHOPS
3-8. General
3-10. Setup of Testing Fixture For General Support
and Depot Maintenance Shops
This section sets forth the procedure to be followed by
maintenance shops in performing inspection of the
Note. In order to perform setup procedures it
telescope when removed from the end item and turned-
will be necessary to use the telescope M120 together
in to the shop for repair.
with mount, telescope M148 and telescope XM134
together with mount, telescope XM164.
3-9. Initial Inspection
a. Place an angle plate (1, fig. 3-1) on a leveled
surface table and secure with a "C" clamp.
Note. If after inspection the telescope requires
b. Place a parallel bar (2, fig. 3-1) on surface table
repair that is not within the scope of direct support
and against angle plate.
maintenance shops it will be forwarded to a higher
level maintenance shop.
1
Angle plate 4931-886-1222
4
Venier height gage 5210-132-5689
2
Parallel bar 5220-242-7514
5
Projector collimator 4931-757-3291
3
Dial indicator 5210-277-8840
Figure 3-1. Setup of testing fixture.